3400 KW 6000V 50HZ MAN COGEN PLANT
Stock #RG2113
Used cogeneration plant with capacity 3.4 MW. Plant started up in 1999 and has 23,301 hours of use by January 2024.
Includes the following major equipment:
- MAN 6L 40/45 diesel engine made in 1998, power 3475 kW, 600 RPM.
- Leroy Somer LSA58 VS65 / 10p alternator, 6000 V, 4357 kVA, Cosφ 0.8, 50 Hz, 600 RPM.
- (2) Alfa Laval PX605 TFD centrifuges (for fuel) made in 1998 with capacity 600 lires/hour.
- Alfa Laval PX705 SFD-30 centrifuge (for oil) made in 1998 with capacity 5700 litres/hour.
- Geal VT80 B12 oil refrigerator, pressure 8 bar, made in 1998.
- GEA Iberica TGR 14-06-42C air cooler, pressure 4 bar, made in 2010.
- Sulzer cooling tower, pressure 3 bar, made in 1998.
- Recovery boiler, pressure 1.83 bar, made in 1998.
Location: Morocco
Add to Cart
View Details
(2) 400 kW 380 Volts 50 Hz Biogas CHP Units
Stock #RG8914
Used 0.8 MW MWM CHP power plant including (2) engines rated 400 kW fuelled by biogas and held in soundproof containers. Made in 2011 and still operating 2 days per month. 19442 and 19633 hours of use recorded by February 2024. Equipment list includes:
- (2) MWM TCG 2016 V08 C engines rated 400 kW electrical output, 395 kW thermal output +/- 8%, electrical efficiency 42.8%, thermal efficiency 42.1%. Gas train, gas mixer, generator, voltage stabiliser, power factor controller, coupling, control unit and switchboard.
- exhaust silencer.
- CHP power cabinet.
- heat exchanger cabinet, heat extraction / hydraulic system, plate heat exchanger, surge tank.
- electrical circulation pump for combustion engine.
- mixture cooling.
- exhaust gas heat exchanger
- soundproofed container, 65db(a) in 10M, emergency cooler, engine control system
Each 400kW engine may be available separately; more information on request.
Location: EUROPE
Add to Cart
View Details
10300 kW Rolls Royce Diesel And Natural Gas Turbine
Stock #RG8549
Used Rolls Royce model Avon 1534-102L dual fuel diesel and natural gas turbine. 10.3-16 MW.
Location: UAE
Add to Cart
View Details
13180 kW 6000 Volts 50 Hz Deutz MWM Cogeneration Plant
Stock #RG9948
Used Deutz MWM cogeneration plant powered by heavy fuel, shut down in February 2021. Plant includes (3) motors as follows:
- Motor 1: Type TBD 645 L 9, 72059 hours of use, 3675 kW. Alternator 6000 volts, 0.8 power factor, 600 rpm, 50 Hz. Start up in 1997.
- Motor 2: Type BV 16 M 640, 72750 hours of use, 6590 kW. Alternator 6000 volts, 767 A, 0.8 power factor, 600 rpm, 50 Hz. Start up in 1999.
- Motor 3: Type TBD 645 L 9, 71221 hours of use, 2915 kW. 600 rpm, 50 Hz. Start up in 2003
Data sheets available after registration.
Location: Europe
Add to Cart
View Details
140 kw Gasification and CHP Plant
Stock #RG9456
Used modular gasification plant made circa 2001 and currently used for R&D purposes. Gasification plant uses 'down draft' process to produce syngas from solid biomass including wood chips and wood pellets.
Equipment includes:
- Feed mechanism
- Gasifier. Top loading down draft type including lock hopper feed mechanism, grate and auto de-ashing. Can use wood pellets and wood chips.
- De-ashing system
- Gas cooler. Water cooled.
- Filtration unit
- Ash hopper collection system
- Piping
- Instrumentation for control panel and PLC
All of the above is installed into modular framework. Plant used for R&D purposes.
Location: United Kingdom
Add to Cart
View Details
26000 kW 13800 Volts 60 Hz GE Dual Fuel Turbine Generator
Stock #ZG62021
Rebuilt 26 MW GE LM2500 dual fuel turbine generator
Current configuration:
Turbine:
manufacturer: GE
turbine engine: 7LM2500-PH-LMB-G03 (STIG-50)
power output: 26,249 kW, at generator terminal
fuel: liquid/gas
hours of operation: 7,141
starts: 816
zero houred and ready to ship
Generator:
manufacturer: Brush Electric Machines Ltd. BADX 7-167ER
type 13.8KV, 60 HZ, 3 phase, 3600 rpm, air
coupling: power turbine to generator
L. O. System: GT L.O. Tank 600L, w/GT driven lube pump,generator L.O. Tank 800L, w/ gen shaft drain pump.
Fuel system: fuel pump, filter, fuel control valve,fuel so valve, flow meter.
Steam/water injection: steam/water injection control valve,flow meter.
Water wash: cleaning tank, nozzle spray manifold.
hyd. Start: hydraulic Lube tank 150L. Change pump, circulation pump, filter, hydraulic oil cooler, electric motor.
Location: South USA
Add to Cart
View Details
32350 kW 13800 Volts 60 Hz General Electric Cogeneration Plant
Stock #ZG61416
Gas Turbine:
Manufacturer: General Electric
Base load rating: 32350 kW
Model: MS6001B , DLN-1
Fuel: natural gas
Generator:
Manufacturer:General Electric
Rating: 40500 'id/a
Voltage: 13,800 V, 3 phase, 60 HZ
pf:0.8
Armature amps: 1694
Field amps: 685
Field volts: 125
Speed: 3600 rpm
History
Year built: 1995
Life time starts: 378
Life time hours: 83082
Last overhaul: 2009
Hours since last overhaul: 17,000
Year shutdown: 6/1/2011
Starting: motor 600 HP
Following items are not included: MCC generator breaker and generator protection relays
Location: South USA
Add to Cart
View Details
32500 kW 6900 Volts 60 Hz Power Plant
Stock #ZS60717
1 Boiler capacity of 80 tons of steam per hour, with pressure 42 kg/cm2, with its
peripherals (air preheater, economizer, washer gases) with MCC and control panel
1 boiler capacity of 70 tons of steam per hour at a pressure of 42 kg cm2 +, with its
peripherals (air preheater, economizer, washer gas) with MCC and control panel.
3 turbo-electric power generators with a capacity of 7,500 kW each, generating a
voltage of 6.9 KV, Westinghouse brand, with capacitors, transformers and control
system detached, MCC (motor control center) and control panel.
1 turbo generator Texas / GE - 10,000 kW, generating a voltage of 6.9 KV with condenser, engine control system and control panel generation
3 cooling tower water, brand Alpina, with capacity of 2,000 cubic meters per hour
each, with CCM and 5 booster pumps brand IMBIL, also with CCM.
2 cooling towers Anhanguera brand, with a capacity of 1,500 cubic meters each time,
with CCM and ARDL 2 pumps of 4,000 M3 / H each.
2 voltage transformers brand WEG, with a capacity of 20/25 MVA, with transforms tion
of 6.9 / 138 KV
1 voltage transformer brand WEG, with a capacity of 2.5 MVA, with conversion of 13.8 /
6.9 KV1 voltage transformer brand WEG, with a capacity of 500 kVA, with transformation
13.800V/380V
1 lift 380-13800 10 KV transformer - 2,500 kVA
1 system generation control and timing with delivery network.
1 water treatment plant with capacity of 50 M3/hr, brand Metágua.
1 system decanting water scrubber with CCM.
Diesel generator set 1
- engine alternator and Cummins - 1500/1250 kVA - 380 V
network 1 power transmission at high voltage (138 KV) 2,100 meters long.
Location: N/A
Add to Cart
View Details
3896 kW, 15000 V, 50 Hz MTU Cogeneration Plant
Stock #RG2162
Used cogeneration plant with output rated 3896kW / 4870 kVA consisting of (2) MTU natural gas synchronous generators rated 1948 kW / 2435 kVA each.
Plant includes:
- (2) MTU model 20V-4000L62 natural gas engines with nominal power 2000 kW, 1500 RPM and turbochargers ABB TPS 52. Both units made in 2010, unit 1 has 44198 hours of use and unit 2 has 42699 hours of use.
- (2) Stamford model LVS I 804 S2 generators, nominal voltage 400 V, power 2790 kVA. Both units made in 2010, unit 1 has 44198 hours of use and unit 2 has 42699 hours of use.
- (2) Siemens main transformers of 2500kVA 0.4/15kV and (1) auxiliary transformer of 250kVA 0.4/15kV.
- Metering system.
- 15kV underground line connected to the switchgear station.
- Alternator.
- Ambitermo steam recovery boiler type horizontal gas-tube with power 932 kW, heating surface area 33,255 m2, steam production 1410 kg/h, operating volume 6009.36 l.
- Grundfos model CR1-27 water supply system with flow rate 1.8 m3/hour.
- Boiler control PLC.
- Low temperature cooling system, high temperature cooling system, plate heat exchanger, circulation pump, cooling module.
- Control room.
Location: Europe
Add to Cart
View Details
41590kW 13800 Volts 60 Hz GE Frame 6B Gas Turbine
Stock #ZG60442
Used General Electric Frame 6B Gas Turbine Generator:
-GE Model 6541B Gas Turbine, Duel Fuel Base Rated 41,590 KW, Water Injected Combustion with Inlet Air Cooled, Heat Rate at ISO 10,860 BTU/KwH, 5100 RPM
-Diesel Black Start Engine
-Philadelphia Gear Box with Atomizing Air Compressor, 650 hp, DWG no 334A7220P001, Input 5100 RPM
-Philadelphia Load Gear HP rating 68391, Model S664A 224H0L-A, Input 5094 RPM Output 3600 RPM
-Resorcon Turbine Inlet Air Cooling System
-Side Exhaust to HRSG
-Water Injection Pump and System for Nox Control
-Worthington Natural Gas Compressor Bore 13.0 Stroke 6XH S/N A19288 and Gas Train
-Liquid Fuel Pump and Supply System
-GE TEWAC Generator Rated 46,500 KVA, 13800 V, 3 Phase, 60 HZ, PF: 0.9, 1945 AMPS, 125 V Exciter Volts , Field Amps 778. 3600 rpm
-Mark IV Control System
-GAC with GE VB1 3000 AMP Circuit Breaker
-Sound Enclosure
History:
Unit Installed 1990, Hot Standby, Shutdown 2020.
Total Hours 86,704.60, Total Starts 2,466.
Last Overhaul 2014 , Approx. 598 Hours Since Last Overhaul, Still Installed.
Location: USA
Add to Cart
View Details
5493 kW 6300 Volts 50 Hz Solar Cogeneration Plant
Stock #ZG59952
Solar TBM-T60S rated at 5493 kW, natural gas fired, with Leroy Somer 6250 kVA brushless generator, 6300 volts, 50 Hz. Turbine package has 14,291 total hours, and 388 starts. Bono recovery boiler for 12 tons/H of steam at 15 bar. The plant was built in summer 2002 and shut down in 2010.
Location: EUROPE
Add to Cart
View Details
58500 kW 13800 Volts 60 Hz Combined Cycle Power Plant
Stock #ZG60177
FR-6B combined cycle power plant with 1 X FR6B gas turbine 1 X HRSG and 1 X steam turbine generator set.
Plant performance:
ambient temperature: 48 deg F
fuel: natural gas
gross output: 58,500 kW
plant heat rate: 8,900 BTU/KWH
Gas turbine generator set:
Gas turbine:
manufacturer of turbine: General Electric
model number: PG6541B
type: Continuous
packaged by: GE
packager model number: 6A1PB148-1
rating (base/peak) 42400 kW
inlet temperature: 48 degrees F
speed: 5,100 rpm
Gear reducer:
manufacturer: Westech
rating: 68000 HP
speed: 5100/3600 rpm
generator:
manufacturer: General Electric
type: Tewac
rating: 46,500 kVA
voltage: 13800 V, 3phase, 60 HZ
speed: 3600 rpm
PF: 0.9
Armature amps: 1845 amps
insulation class: F/F (Stator/rotor)
control: Mark IV Speedtronic
black start: diesel engine
fuel: natural gas
NOx control: steam injected
year built 1992 shutdown: Still connected
total life time hours 46,200
hours since last major overhaul 2007 : 1000 hours
HRSG:
manufacturer: Zurn
type: duel pressure
steam flow:
HP super heated steam: 900 PSIG/900 deg F, 147,726 lbs/hr
LP saturated steam: 185 PSIG/384 EF F, 24,623 lbs/hr
Steam turbine generator:
manufacturer: GE
rating: 16,500 kW
pressure temperature flow
inlet steam: 900 PSIG 900 deg F 132,000 lbs/hr
controlled steam: 180 PSIG 0 to 80,000 lbs/hr
exhaust steam: 2" HGA 137,400 lbs/hr
rating with zero extraction: 16,500 kW
steam rate: 8.00 lbs/KWH
speed: 5362 rpm
inlet steam size: 10"
AE steam size: 8"
uncontrolled steam size: 6"
exhaust steam: 75"
governor: Woodward 505E
generator:
manufacturer: GE
rating: 18,333 kVA
voltage: 13800 V, 3 phase, 60 HZ
pf: 0.9
speed: 1800 rpm
Armature amps: 767 amps
exciter: brushless, PMG
type: Tewac
condenser square ft: 16,619 sq ft
condenser water flow: 15,947 GPM
cooling water inlet temp.: 75 deg F
cooling water outlet temp: 92 deg F
History of steam turbine generator:
Steam turbine generator was installed in 1990.
Approximately 50,000 hours
Water treatment system:
Power house building with 15 ton and 20 ton cranes
115 KV substation, 13.8 KV switchgear, 4160 V motor starters, 480 V MCC, battery and battery charger, ups.
Plant history: start up 1992 and operated until 1998, after this date the plant ran as peak standby only
Location: USA
Add to Cart
View Details
5949 kW, 15000V, 50 Hz MMU/MTU Cogeneration Plant
Stock #RG2165
Used cogeneration plant consisting of (1) MWM natural gas synchronous generator set with capacity 4389 kW and (1) containerised MTU natural gas synchronous generator set with capacity 1560 kW.
Plant includes the following equipment:
- MWM TCG 2032 V16 natural gas engine made in 2011 with nominal power 4389 kW / 5486 kVA, 1000 RPM, turbochargers ABB A-140-H56. Hours of use 44,765 hours.
- AVK Generator Model DIG 156 m/6 made in 2011 with nominal voltage 6000v, power 5984 kVA. Hours of use 44,198.
- Ambitermo RSV-V-570 steam generator unit type recovery, vertical waterrube evaporate bundle with economiser. Power 1580kW, heating surface 887.28m2, steam production 2550kg/hour, operating volume 385l.
- Steam boiler drum, feed water system and boiler treatment, security system and boiler treatment.
- Control room.
- Substation unit with 1 Transformer and switching cells of 6000 kVA 6/15 and one auxiliary unit of 250 kVA 0.4/15 kV.
- Metering System.
- 15000 V air ground line connected to the switching station.
- MTU model 16V 4000L62 natural gas engine made in 2011 with nominal power 1600kW / 1935 kVA, 1500 RPM, turbochargers ABB type TPS 57E01. Hours of use 40,769.
- Ambitermo RSB-H-1130 gas tube recovery boiler made in 2012. Power 784 kW, heating surface 242.49 m2, steam production 1000 kg/hour, working volume 6692l.
- Transformation and switching station with one transformer of 2000 KVA 0.4/15 KV
- Measurement equipment.
Location: Europe
Add to Cart
View Details
600 kWe 230/400 Volts 50 Hz Cogeneration Plant
Stock #RG2161
Little used 600 kWe cogeneration plant with only approximately 575 hours of use. Perkins engine rated 600 kWe, 1500 RPM, 230/400 V, 50 Hz.
Location: Europe
Add to Cart
View Details
6600 kW 6000 Volts 50 Hz Cogeneration Plant
Stock #RG9671
6.6 MW 6000 Volts 50 Hz cogeneration plant reportedly made circa 2000 and shut down in 2010 due to rising gas prices. Approximately 34,300 hours of use. Main equipment includes:
- Umisa firetube steam boiler, flow rate 20 tons/hour, pressure 7-8 bar, temperature 170 degrees Celsius, 15.2 MW burner power, volume 55.1 m3, fueled by natural gas.
- (2) Ulstein Bergen KVGS-18G3 engines, 18 cylinders with diameter 250mm, 300mm stroke, 14.7dm3 stroke volume/cyclinder, 1000 rpm, 4 stroke, turbocharged, cooling air intake, designed for natural gas. Otto cycle.
- (2) Leroy Somer power generators, 6000 V, 3-phase, 50 Hz, power factor 0.8.
- ABB Transformer, ratio 22/6.3kV, 8000 kVA.
- ABB low voltage transformer, ratio 6/0.4 kV, 630 kVA.
- Water treatment equipment, osmosis process.
- Cooling tower, 4kW fan power, hot water flow 344m3/hour.
- Ventilation system.
- Compressed air system including (2) Sperre compressors with working pressure 31 bar, 9.5 kW motor, 1.73m3/min.
- (2) Termojet air storage tanks, capacity 1m3 each.
Location: Europe
Add to Cart
View Details
7200 KW Solar T70 Cogen Plant
Stock #ZG62872
Used 7MW Natural Gas Fired Co-Generator Plant:
2015 Solar Taurus 70 Gas Turbine; Rated at 7200 KW, 13,313 Hrs., with 290 Starts, Hyundai Electric Generator 12,470 V, 60 Hz.
Cleaver Brooks HRSG with Natcom Lo-Nox Gas Burner with Ammonium Injection System.
Boiler Capacity: 165K Lbs/HR @650F; Operating Pressure 150 PSIG.
Drawings and Service Records Available.
Location: West Coast USA
Add to Cart
View Details
7832 kW 11000 Volts 50 Hz Deutz Cogeneration Plant
Stock #RG8999
Used 7832 kW, 11000 V, 50Hz cogeneration plant that started operating in 2005 and was shut down in 2019.
Includes (2) Deutz (MWM) TBG 632 V 16 engines fuelled by natural gas. Engines have approximately 45,000 to 50,000 hours of use.
- Each TBG 632 engine has the following specifications: 3,916 KWE, 16 cylinders, speed 1000 rpm, electrical efficiency 41.9%, thermal efficiency 44%, exhaust gas flow 20897 kg/H, gas temperature 466 degrees Celsius.
- Steam generation specifications per engine: max steam flow with exhaust gases from engine 3 TPH, normal operating pressure 7.5 bar.
Equipment list includes:
- engines, generators, plate heat exchangers, oil tanks (fresh and waste), oil heat exchangers, platforms, ventilation canals, boilers, deaeroator, economisers, bypass valves (dampers), stacks, feeding pumps, platforms, pumps, heat exchangers, control panels and transformers.
Each Deutz system is available separately.
More details available on request.
Location: Europe
Add to Cart
View Details
800 kW 380 Volts 50 Hz Biogas Power Plant
Stock #RG8915
Used 800 kW landfill biogas power plant reportedly made in 2011. Still operating and currently (February 2024) with 19442 and 19633 hours of use. Plant includes the following equipment:
- gas extraction system with capacity 500 M3/hour. Option to increase capacity to 1000 M3/hour with additional compressor.
- system with vertical wells can cover 3.2 ha, system with horizontal wells can cover 7.5 ha of landfill area.
- remote monitoring.
- high temperature flaring unit. Landfill gas burning temperatures between 1000-1200 degrees Celsius.
- (2) 400 kW container based MWM TCG 2016 V08 C engines.
Plant information sheet available on request.
Location: EUROPE
Add to Cart
View Details
8778kW, 60000V, 50 Hz MWM Cogeneration Plant
Stock #RG2164
Used cogeneration plant with output rated 8778kW / 10972 kVA consisting of (2) MWM natural gas synchronous generator sets rated 4389 kW / 5486 kVA each.
Plant includes:
- (2) MWM model TCG 2032 V16 natural gas engines made in 2011 with nominal power 4389 kW, 1000 RPM, Turbochargers ABB A-140-H56. Hours of use 42,209 and 42,047.
- (2) AVK model DIG 156 o/6 generators made in 2011 with nominal voltage 15000V, power 5373 kVA, PF 0.8. Hours of use 44,198 and 42,699.
- (2) Ambitermo RSB-V 858 steam recovery boilers type vertical watertube evaporative bundle with economiser. Power 1770 kW, heating surface 858.42 m2, steam production 5430kg/hour, operating volume 6009.36l
- Ambitermo EV5430 horizontal steam boiler drum.
- Feedwater system, safety systems and spares.
- Control room
- Substation unit with (2) transformers and switching cells each 2500 kVA, 15/60kV ad (1) auxiliary unit 2500 kVA, 0.4/15kV.
- Metering System.
- 15000 V Underground line connected to the switching station.
Location: Europe
Add to Cart
View Details
Biomass Power Plant 5000 kW
Stock #HG62483
Used wood biomass power plant with the electrical output 5000 KW/h. Main equipment of the plant - Boiler Weiss with 25.5 TPH / 65 bar / 480*C steam output, and steam turbine MAN with 5 MW / 63 bar / 477*C. Fuel, wood chips with the moisture content of up to 50%. More information on request.
Location: Europe
Add to Cart
View Details
Solar T70 Gas Turbine Package
Stock #ZG63017
Used Solar Taurus T-70 Gas Turbine Package, 7.1MW, 60Hz, 13,800volts, Emission SoLoNoX 25-PPM (dry low NoX), Fire System, Air Filtration, and Switchgear. More information available, extremely low hours.
Location: Midwest USA
Add to Cart
View Details
Used 3.5 MW Cogen Plant consisting of Solar Turbines Centaur 4701
Stock #ZG63843
Used 3.5 MW Cogen Plant consisting of a Natural Gas Turbine Driven Generator Set Solar Turbines Centaur 4701
Solar Turbines Centaur 40. Model 4701, Natural Gas Fired, Generator rated at: 4375 kVA. 4160 Volts. 3 ph. 3.5 MW. 60 Hz. Energy Recovery Intl Boiler: Type S2.5-2016 with Economizer. Serial number W-3173/E-3174. Total heating surface 14,617 sq ft. Design pressure 425 psig. Operating pressure 375 psig. Temperature of feedwater to be furnished to unit 219F. Continuous steam capacity 40,000 lbs/hr. Water capacity when flooded 10,725 lb 1,285 Gal. Water capacity at operating level 8,000 Lb 960 Gal. Total tubes 320. Tubes 2 in O.D.
Plant is 2021, and is still in operation. Gas Turbine has 135 Starts and 16,711 hours reported in August 2024.
Location: West Coast USA
Add to Cart
View Details
365 KW 400V 50HZ HOVAL KWK EG-365 CHP
Stock #VL1457 Sold
Used Hoval KWK EG-365 containerised CHP Unit. Rated 365kw electrical power output and 496kw thermal power output. Fed by natural gas. Maximum operating pressure 6 bar. Mounted in 25ft steel container.
CHP module includes:
MAN E2842 LE322 natural gas Otto engine. 1500rpm
Stamford HC.I534D synchronous generator.
Automatic oil supply lubrication system with clean oil tank.
Engine cooling water and exhaust gas heat exchangers.
Microprocessor controlled electronic ignition and starting system.
Gas control system with mixture device and motor driven control valve.
Custom control and measurement system to regulate the CHP module.
Heat Extraction system (mounted externally on top of the steel container)
Location: Perry England Warehouse
View Details
79000 kW 50Hz Combined Cycle Power Plant
Stock #VL1534 Sold
Used 79mw combined cycle cogeneration plant consisting of: (1) 40mw GE model Frame 6 gas tubine engine with gear box and generator. (1) Standard Fasel Lentjes single pressure HRSG. Unit rated design pressure at 76bar, approximately 67.5ton/hr of steam at 460 deg.c. (fed from fresh water at 70 deg.c.) (1) 39mw ABB steam turbine with gearbox and generator.
Location: UK
View Details
10600 kW 12470 Volts 60 Hz Solar Mars Combined Cycle Power Plant
Stock #ZG61353 Sold
Used 10.6 MW combined cycle power plant consisting of a Solar Mars 100-S gas turbine generator, with HRAG, and steam turbine generator.
Gas turbine:
manufacturer: Solar
type: 100S
rating: 10690 kW (ISO)
version: 15000S
heat rate: 10,515 BTU/KWH (ISO)
fuel: natural gas
generator: 13125 kVA, 12470 V, 60 HZ, 0.8 pf
HRSG:
40,000 lbs/hr 150 PSIG
Steam turbine: Murray
History:
built 1995, shutdown 2008, lift time 90,000 hours, since last overhaul 34,000 hours
This combined cycle power plant with 138 KV substation.
Location: USA
View Details
115000 kW 50Hz GE Power Plant
Stock #RG9341 Sold
Used 115 MW dual fuel GE Power Plant made during 1997/1999 and now decommissioned. Hours of use are GTG1 111535, GTG2 100533. Last major overhaul was 2007 (STG), 2004 (GTG1) and 2006 (GTG2). GTG1 and GTG2 have since had 42118 and 56004 hours of use respectively. Plant includes the following major equipment:
- (2) GE Frame 6B 40 MW Gas Turbine Generator Sets made in 1997.
- Siemens 40 MW Steam Turbine Generator made in 1999.
- Desa-BWG Heat Recovery Steam Generator (HRSG) with capacity 61.2 tons/hour of steam made during 1997/1998.
Gas turbines also available separately.
Location: Europe
View Details
130000 kW 50 Hz GE Power Plant
Stock #RG9336 Sold
Used 130 MW dual fuel GE Power Plant made during 2001/2002 and now decommissioned. Hours of use are GTG1 80100, GTG2 79400. Last major overhaul was in 2009 and GTG1 and GTG2 have since had 35,700 and 36,600 hours of use respectively. Plant includes the following major equipment:
- (2) GE Frame 6B 40 MW Gas Turbine Generator Sets made in 2001.
- Siemens 50 MW Steam Turbine Generator made in 2002.
- Standard Fasel Heat Recovery Steam Generator (HRSG) with capacity 65 tons/hour of steam made in 2002.
Gas turbines also available separately.
Location: Europe
View Details
1649 kW 400 Volts 50 Hz Jenbacher Cogeneration Plant
Stock #RG2153 Sold
Used Jenbacher J420GS B04 CHP power plant, made in 2011, last used in February 2024 and with 40,337 hours of use. Power rated 1649 kW (at 2000m altitude) and 50Hz.
Equipment includes Jenbacher J420GS B04, control panel Dian XT, radiator, silencer, transformers 20kV / 400V, heat exchanger.
Location: Europe
View Details
2400 kW 11000 Volts 50 Hz Waukesha Gas Fired CHP Plant
Stock #RG8154 Sold
Used Waukesha 2.4MW gas fired CHP plant. Main components of the plant are (1) Waukesha model 12V-AT27GL gas fired engine with a Leroy Somer alternator rated at 2400 kW, 50 HZ, 11,000 volts. Natural gas compressor, starting air compressor with receiver, exhaust system, heat recovery boiler, lube oil system, and fire suppression system. Includes switchgear, computer and national grid synchronisation system. The generator is housed in an acoustic enclosure.
Location: UK
View Details
25000 kW 11000 Volts 50 Hz Siemens CHP Plant
Stock #ZG61803 Sold
Used 2001 Siemens GT10-B2 natural gas fired turbine generator CHP plant, DLE pg, rated at 25 MW with ABB generator rated at 26,250 kVA, 11KV +/- 5%.
Operating hours: 47,656 hours
equivalent hours: 43,911 hours
total starts: 224
total production: 967,906 MWH
Location: EUROPE
View Details
300 KW BIOMASS POWER PLANT
Stock #HG62481 Sold
Used wood biomass power plant with the electrical output 300 KW/h. Power plant from Italy that has been in operation for about 1 month. The electrical hourly power output (when summed on the 4th turbines) is 300 kWel (two gas turbines and two ORC turbines). The waste heat from the plant is about 1 MW of hot water with an indicative consumption of 600 kg of wood chips/hr with a humidity of 40%. The boiler is a Kohlbach K8 (Austria) technology with an output of 2 MW.
The power plant consists of:
hydraulic floor - 3 pistons
hydraulic dosing conveyor / single machine located below level "0"
biomass boiler Kohlbach 2MW
hydraulic aggregates
screw compressor and air bags
two exhaust particle filters
two gas turbines - each in its own container
cooling flue gas exchanger for ORC equipment
particulate filter in the flue gas
flue gas analyzer
flue gas fan with chimney
ORC equipment in a complete block (container) there are two ORC turbines
Cooling tower - individual cooling towers with fans
Emergency heat exchanger for ORC cooling
Electrical switchboard in a separate container
fire system with power plant in a separate container
Location: EU
View Details
34920 kW 11000 Volts 50 Hz Wartsila Power Plant
Stock #RG8220 Sold
Used 34920 kW Wartsila power plant comprising of the following:
(4)used 8730 kW Wartsila 20V34SG (spark gas) units. Power 8,730 KWH X 4 (units) = 34,920 KWH. Fuel 100% natural gas. First used in 2005, run for 48,000 hours. Consists of:
(4) generators. Capacity 10,913 kVA, frequency 50 Hz, cos 0.8, volt 11,000 V output;
(4) neutral cubicles;
(4) step-up transformers. 11kV/33kV 11 MVA Onan/ONAF 33 kV, 5 steps output;
start air compressors;
(4) boilers. Pressure 13 Barg saturated stream, steam capacity 4.7 ton/HRS production;
(4) cooling towers.
Location: EUROPE
View Details
419.9 MW Combined Cycle Power Plant Fuel Type Natural Gas
Stock #KS61696 Sold
Reportedly unused 419.9 MW combined cycle power plant Siemens. Turbine Siemens type SGT3-4000, Steam turbine Siemens type SST5-3000, condenser Scin, automated system for GT and ST: SSPA-T3000. Requires new generator, old generator is damaged. Totally 475 units in cargo. It is power plant based on Combined Cycle Gas Turbine using after burning of gas recovering of heat in Condenser for Steam turbine for more power output. More info upon request.
Location: EUROPE
View Details
4200 kW 11000 Volts 50 Hz Siemens Power Plant
Stock #RG7655 Sold
4.2MW Typhoon frame mounted power plant. Natural gas & diesel fuel configuration. Main gearbox and alternator included rpm 1500. Please see attached document for full technical details.
Location: TURKEY
View Details
4500 kW 10000 Volts 50 Hz Turbo Mach Spa. Turbo Gas Cogen Plant
Stock #RG7305 Sold
Used 4500 kW 5750 kVA 50Hz turbo gas cogen plant. Manufacturer Tuma - Turbo Mach spa.
Year of manufacture 1995. New turbine and generator in 2001.
Fuel: natural gas (CH4)
gas comsumption: 1.200.000 M3/month; 65/70% for power, 30/35% for steam
gearbox reductor cat-solar
Leroy Somer power generator for 4.6 MW / 5750 kVA at 10.000 V, 1500 rpm
solar centaur 50-T6200 gas turbine
bono heat recovery boiler, with 10 ton/hr steam production at 10 bar
water demineralization system with condensate recovery and make-up water tank
degaser, 2 high pressure pumps for boiler feeding
automatic turbine washer
Location: EUROPE
View Details
4900 kW 600 Volts 50 Hz Siemens Power Plant
Stock #RG8415 Sold
Used 4.9 MW, 6000/15000V, 50 Hz power plant. Reported to be in good condition and to have been regularly overhauled according to Siemens regulations. Plant consists of the following main elements:
- Siemens SGT 100 dry low Nox gas turbine made in 1997. Power 4.9 MW, frequency 50 HZ, efficiency 31%, heat consumption 11.613KJ/KWH, power turbine speed 17,384 min-1, compressor pressure ratio 15.6:1, mass flow 20.6kg/S, exhaust temperature 531 degrees Celsius, hours since last overhaul 4000.
- Babcock heat recovery steam generators made in 1997. Steam 30 tons/hr, pressure 20 bar.
- Bolletino transformer made in 1997. Output voltage 6000 / 15000 volts, phases 3, power 6090 kVA, power factor 0.8, speed 1500 rpm, protection IP 3.
Location: EUROPE
View Details
53000 kW 11000 Volts 50 Hz Combined Cycle Cogeneration Power Plant
Stock #RG7793 Sold
Used 53MW combined cycle cogeneration power plant consisting of the following:
(1) off used GE (Nuovo Pignone) model FRMS 6001 (B) 6541 gas turbine. Power rating ISO 39MW with efficiency rating 31.9%. Natural gas / distillate oil fuel configuration but only used on natural gas since new. Unit includes steam injection. Unit includes electric motor + torque converter for start-up. Unit is mounted in acoustic booth and skid mounted.
(1) off used Flender-Graffenstaden main gearbox type TRL 65 CV. Unit rated 5113.6 rpm input with 3,000 rpm output.
(1) off used GEC Alsthom turbine generator. Power output rated 46,000 kVA, 3,000 rpm, 50 hertz. Power factor 0.85, 39,100 kW, 2414 amps, 11,000 volt, insulation class F. Cooling system CACW.
(1) off used auxiliary boiler rated 60 ton/hour with economiser and auxiliary combustion system.
(1) off used Ansaldo steam turbine model CDI 635 R, power rating 18,700kW. HP inlet pressure at 68.5 bar at 498 deg.C with flow of 64.5 T/R in winter, 11a=MP-11A extraction pressure rated 14.5 bar at 315 deg.C. LP inlet pressure operated between 6 bar to 6.4 bar at 280 deg.C. With flow of 13.5 T/H.
(1) off used Ansaldo steam turbine generator, power output 23,000kVA, 11,000 volt. Cooling system CACW.
(1) off used reverse osmosis water treatment plant with double resin DEMI line with final mixed bed.
(2) off used reciprocating gas compressors rated 11-19.5 bar pressure.
(2) off used Ingersoll Rand model SSR M55/75 air compressors.
(1) off used ingersollrand model SSR M22 air compressor.
(4) off used transformers.
Electrical equipment includes: GEC Alstrom AKG 400 L18 motor control centre, ABB generator control panel and ABB synchronising.
Balance of plant includes: turbine control system Mark V, air intake/filtration system, exhaust silencer, oil cooler, fire & gas system with detectors.
Plant commissioned in 1994 and last ran in 2010.
Location: EUROPE
View Details
8730 kW 11000 Volts 50 Hz Wartsila Gas Units
Stock #RG8191 Sold
Used 8730 kW Wartsila 20V34SG (spark gas) units. Power 8,730 KWH. Fuel 100% natural gas. First used in 2005, run for 48,000 hours.
Equipment has reportedly been used for approximately 1500 hour since last overhaul. The plant consists of:
- Generators. Capacity 10,913 kVA, frequency 50 Hz, cos 0.8, volt 11,000 V output;
- Neutral cubicle;
- Step-up tranformer. 11kV/33kV 11 MVA Onan/ONAF 33 kV, 5 steps output;
- Start air compressor;
- Boiler. Pressure 13 Barg saturated stream, steam capacity 4.7 ton/HRS production;
- Cooling tower.
Location: EUROPE
View Details
Solar T70 Gas Tuebine Cogeneration Plant
Stock #ZG63492 Sold
Used 7 MW Cogeneration Plant consisting of a Solar Taurus 70 Gas Turbine Rated at 7.432 KW, Voltage 12,470, Hours 12,205, Heat Rate 10,149 BTU/KWH, Rentech Waste Heat Boiler, Trane/Thermax LiBr Absorption Chillers, SCR, Gas Compressor, MCC, and Ancillary Equipment.
Location: Northeast USA
View Details
Used Cogeneration Plant With Power 2.4 KW
Stock #UG6358 Sold
Used cogeneration plant by Caterpillar working on natural gas. Consist of two motors type G3516C, each with power 1.2 MW. Total power 2.4 MW.
Location: Poland
View Details
Used gas engine cogeneration plant 2000 KW
Stock #L0909 Sold
Used gas engine cogeneration plant with total electrical output of 2000 KW, 50 Hz, 400 V.
Main equipment of the plant:
Gas engine generator Deutz type TBG-604 for 525 KW.el
Gas engine generator Deutz type TBG-604 for 525 KW.el
Gas engine generator Deutz type TBG-620 for 1000 KW.el
Heat recovery units.
Fuel - natural gas.
More information on request.
Location: EUROPE
View Details