10000 kW 42/6 Bar Steam Turbine/Generator
Stock #ZS60722K
Used set steam turbine/generator. Mfg : TGM power: 10000 kVA model : TM 15000a year of manufacture : 2001 type : pressure rated speed : 8000 inlet pressure : 42 bar exhaust pressure : 6 bar steam temperature input : 420 є C flow inlet steam : 65 ton / H ( 5MW ) specific consumption : 13 ton / MW ( current status ) gear : PTI power/transmission Industries reduction : 1,444 rotation of entry : 8000 power : 9470 kW service factor : 1.37 power generator Mfg : WEG model : SSW 800 year of manufacture : 2001 rated speed : 1800 rpm active power: 10000 kVA output voltage : 13,800 V current : 418.4 a frequency : 60 HZ insulation class : F
Location: BRAZIL
11000 kW 715/200 PSI Turbodyne Non-Condensing Steam Turbine
Stock #ZG60222
Turbodyne non-condensing steam turbine 11,000 kW, 3600 rpm, 715 PSIG in at 725 degree F, 200 PSIG exhaust. Steam flow at full load: 375,000 lbs/hr generator electric machinery 13,450 kW, 15,825 kVA 13,800 volts, three phase, 60 Hz, 0.85 pf, 662 amps shut down NOV. 1998. Still installed. Scope of supply: steam inlet valve. Steam exhaust valve. Turbine turning gear. Turbine Lube oil system, L.O. Tank, coolers, oil filters with controls, etc.
Location: USA
1500 kW 15 Bar Kaluga Steam Turbogenerator Set
Stock #AG61861-02
Used back pressure steam turbogenerator set by Kaluga type op-1.5-3. Nominal capacity 1500 kW. Inlet stem flow pressure 15-21 bar, temperature 350*C. Back pressure 3 ATM. Size parameters - length 2961mm, width 2090mm, height 2262mm.
Location: EUROPE
16000 kW Steam Turbine Generator Set
Stock #RG9620
Used 16000 kW back pressure steam turbine generator set made 2007 and shut down December 2017. Sale includes: - MAN Marc 4B steamturbine, made in 2008, capacity 16230kW, nominal speed 8120 rpm, fresh pressure steam 99 bar, consumed fresh steam 129.2 tons/hour, pressured finished steam 7 bar, temperature fresh steam 410 degrees Celsius, temperature used steam 165 degrees Celsius. - Lubrication system made by Reinhold Wesselmann GmbH in 2007. - Control oil system made by Hydac Systems GmbH in 2007. - Gear box / transmission made by Renk AG in 2007 with nominal power 17050 kW, configured power 18650 kW, 8120 / 1500 rpm. - Generator made by Jemont Electric in 2008 with power 16240 kW, 20300 kVA, 10500 V +/- 5%, 1116 A, 50Hz, 1500 rpm, 0.8 power factor, total hours logged 60,145. - Fire extinguishing system made by Van Wijk en Boersma in 2008. - Central control and operating cabinets. - Steam characteristics at inlet of steam turbine under normal operation at max load: 99 bara, 400 degrees Celsius, max flow 129.2 tons/hour. - Steam characteristics at exhaust at max: 7 bara, 165 degrees Celsius, 129.2 tons/hour.
Location: Europe
2,500 Kw 298 Psi Triveni Back Pressure Steam Turbine Generator
Stock #ZS63426
Used Triveni (India) back pressure Steam Turbine Generator Set rated at 2,500 kW, new in 1988. Consisting of: - Triveni (India) type 550mm back pressure steam turbine, new in 1988, with inlet steam pressure 21 kg/cm2 @ 340 Deg.C, and exhaust steam pressure 1/1.2 kg/cm2. With Triveni (India) gearbox, new in 1988, input speed 8250 rpm and output speed 1500 rpm, ratio 5.5/1. Turbine & Gear box alongwith coupling mounted on common baseframe (oil tank). - Kirloskar Electric Co. Ltd alternator frame 4AB710/6, new in 1994, capacity 3125 kVA voltage 420V 3phase 50Hz, mounted on baseframe, - Alternator coolers, oil coolers, AOP, valves, extension piece. - Governing System More details upon request.
Location: ASIA
2,500 Kw 597 Psi Ape Belliss Back Pressure Steam Turbine Generator
Stock #ZS63425
Used APE Belliss (India) back pressure Steam Turbine Generator Set rated at 2,500 kW, new in 1993. Consisting of: - APE Belliss type HES-14 steam turbine, new in 1993, with inlet steam pressure 40 kg/cm2 @ 400 Deg.C / Maximum 42 kg/cm2 @ 440 Deg.C., and exhaust steam pressure 5 kg/cm2/ maximum 7 kg/cm2. With Triveni (India) gearbox type HSG-450-91/4, new in 1993, input speed 10250 rpm and output speed 1500 rpm. Both mounted on baseframe. - Kirloskar Electric Co. Ltd alternator, new in 1994, capacity 3125 kVA voltage 420V 3phase 50Hz, mounted on baseframe, - Alternator cooler, oilc filters and coolers, U bends, valves, AVR panel. Exclusions: Low Speed Coupling, Alternator Control Panel, etc. More details upon request.
Location: ASIA
2000 kW 24/2.5 Bar Atlas Dual Back Pressure Turbine
Stock #ZS60714
Used 2000 kW Atlas dual back pressure turbine C - 700 TE with the gearbox connected with coupling to a Skoda 1994 generator. The generator is coupled with the turbine on a steel frame. Single-stage steam turbine with an integrated gearbox. Self turbine stage is attached to the gearbox with one high-speed pinion on which is mounted the turbine impeller with two-stage axial blading type C. The cabinet is mounted on transmission. Bearing lubrication gear is protected from the oil system generator. Rated parameters steam parameters * input 2.4 [MPA ABS.] 350 [° C] output 0.25 [MPA ABS.] 210 [° C] rpm 6000/3000 [min-1] steam consumption, performance steam flow 30 [T.H-1] rated power 2000 kW generator rated voltage:6300V, 3 phase EL. Performance in 2500 [kW] at the terminals of electrical generator regulation turbine operation ensures by electronic regulator tr 101 and Electro-hydraulic oil, low pressure unit Voith. By oil pressure unit is controlled regulatory quick-closing valve. Turbine regulation allows these types of operation: -speed control maintains the desired speed during turbine start-up, before connecting the generator to the electric net, during the controlled shutdown after disconnecting the generator. -backpressure-regulation the control works only when running the generator sets connected to the electric net. Flow steam turbine is determined by immediate collection of steam appliances and electric power corresponds to this flow (which made electrical power should be used). Pressure regulators maintain a constant (adjustable) backpressure. - oil management for lubrication of bearings and gearwheels of transmission: - main gear driven oil pump which supplies pressurized oil for lubrication of turbines in operation (gear). Approach-electric oil pump - emergency oil pump driven by an electric motor for supplying pressure oil for lubrication and cooling of bearings at full power failure (power supply from an Independent source such as ups). Oil-tank has a volume of about 400 liters. For lubrication can be used turbine oil TB-46 or equivalent, complying with IEC 65 6620. -oil cooler (2 X plate L25 GG 60) to aggressive cooling water. Flow of water max 20 ° C is about 8.4 +5.2 T.H-1, the cooler pressure loss is about 35 KPA warming water of 8 ° C. Required cooling water over pressure of 0.6 MPA. For cooling is considered chemically treated water: content of mechanical particles max ............ 50 mg.L-1 PH ................................................. ...... 7 ÷ 8.3 hardness ................................................. .. 4 to 7 mg EQ. Content of impurities ............................. 700 to 1000 mg.L-1 it is recommended to insert to the water circuit coke filter -two oil filters - each containing: 6X insert CFO 11942 25 microns.
Location: EUROPE
2000 kW 348 PSI Atlas Dual Turbine
Stock #ZS60722F
Used Atlas model C-700TE dual turbine. New in 1986. Maintenance in 2008. Turbine with the gearbox is connected with coupling to generator, the generator is coupled with the turbine on a steel frame. Single-stage steam turbine with an integrated gearbox. Self turbine stage is attached to the gearbox with one high-speed pinion on which is mounted the turbine impeller with two-stage axial blading type C. The cabinet is mounted on transmission. Bearing lubrication gear is protected from the oil system generator. The nominal parameters of the turbine Atlas C - 700 TE required quality of steam according to CSN 07 7401 allowable increase in pressure and temperature on a quick valve according to EN 60045-1 rated parameters steam parameters * input 2.4 [MPa ABS.] 350 [° C] output 0.25 [MPa ABS.] 210 [° C] rpm 6000/3000 [min-1] steam consumption, performance steam flow 30 [t.h-1] rated power 2000 kW generator rated voltage: 3 kV x 6300 EL. Performance in 2500 [kW] at the terminals of electrical generator regulation turbine operation ensures by electronic regulator tr 101 and electro-hydraulic oil, low pressure unit Voith. By oil pressure unit is controlled regulatory quick-closing valve. Turbine regulation allows these types of operation: -speed control maintains the desired speed during turbine start-up, before connecting the generator to the electric net, during the controlled shutdown after disconnecting the generator. -Backpressure-regulation the control works only when running the generator sets connected to the electric net. Flow steam turbine is determined by immediate collection of steam appliances and electric power corresponds to this flow (which made electrical power should be used). Pressure regulators maintain a constant (adjustable) backpressure. Oil management oil management for lubrication of bearings and gearwheels of transmission: - main gear driven oil pump which supplies pressurized oil for lubrication of turbines in operation (gear). Approach-electric oil pump - emergency oil pump driven by an electric motor for supplying pressure oil for lubrication and cooling of bearings at full power failure (power supply from an Independent source such as ups). Oil-tank has a volume of about 400 liters. For lubrication can be used turbine oil TB-46 or equivalent, complying with IEC 65 6620. -oil cooler (2 x plate L25 GG 60) to aggressive cooling water. Flow of water max 20 ° C is about 8.4 +5.2 t.h-1, the cooler pressure loss is about 35 KPA warming water of 8 ° C. Required cooling water overpressure is 0.6 MPa. For cooling is considered chemically treated water: content of mechanical particles max ............ 50 mg.l-1 PH ................................................. ...... 7 ч 8.3 hardness ................................................. .. 4 to 7 mg eq. Content of impurities ............................. 700 to 1000 mg.l-1 it is recommended to insert to the water circuit coke filter -two oil filters - each containing: 6x insert CFO 11942 25 microns.
Location: N/A
20700 kW 1325/475 PSI General Electric Steam Turbine Generator
Stock #ZG60772
Used 20.7 MW General Electric 8 stage back pressure steam turbine generator, manufacture year 1987, counter clockwise rotation, steam inlet 1325 psi @ 900 F, 475 psi extraction and 70 PSIG exhaust, air cooled general electric generator is rated at 3600 rpm, 13,800 volts, 3 phase, 60 HZ. Last major overhaul 10/2007 operating hours since last overhaul 10,390.
Location: USA
3000 kW 360 PSI Allis Chalmers Non-Condensing Steam Turbine Generator Set
Stock #ZG60118
3000 kW Allis Chalmers Non-condensing steam turbine generator set, 360 PSIG @ 670-720°F, 20-40 PSIG exhaust, 3/60/4160 V, 3600 rpm. 9 stages (1-Curtis, and 8-Rateau).
Location: Midwest USA
34000 kW 800 PSI General Electric Steam Turbine Generator Set
Stock #ZG59604
Used GE 34MW back pressure steam turbine generator set with auto extraction. Manufacturer: Canadian GE rating: 34000 kW inlet steam: 800 PSIG/825 deg F max inlet steam flow: 640,000 lbs/hr extraction steam: 150 PSIG extraction flow: 0 to 500,000 lbs/hr exhaust steam: 75 PSIG exhaust flow: 0 to 500,000 lbs/hr speed: 3600 rpm generator: rating: 40,000 kVA volts: 13800V/3/60 HZ year built: 1972 year shutdown: 2007 scope of supply: steam turbine generator unit with all associated equipment still installed.
Location: USA
4000 kW 40/3 ATI Kaluga Turbogenerator
Stock #ZS60234
Used 4000 kW Kaluga turbogenerator. 40/3 ATI. 450 celsius temperature. 50HZ .
Location: N/A
800 HP Coppus RLA23E Non-Condensing Steam Turbine
Stock #ZG63612
New/Unused 813 HP (700 HP) Coppus/Dresser-Rand. Model RLA23E non-condensing mechanical drive steam turbine. 493/544 psig @ 507°F, 47-55# BP exhaust, 3558/1750 RPM. Lufkin reduction gear. All mounted on common structural steel base with Marland Clutch and Oil Cooler. Manufactured 2007. Turbine Specifications Serial No.: 06T7856 HP: 800HP Inlet Pressure: 493/544 psig Inlet Temperature: 504°F Trip Speed: 4,127 RPM Maximum RPM: 3,558 RPM Form: RLA23E RPM: 3558/1760 Exhaust Pressure: 55 psig Exhaust Temperature: 400°F Steam Rate: 26.2 #/HR Inlet: 4” @ 600# Flange Exhaust: 8” @ 150# Flange Gear Specifications Manufacturer: Lufkin Serial No.: 119735 HP: 800 Service Factor: 1.87 Pinion RPM: 3558 Form: AGMA#3 Ratio: 2.022:1 Gear RPM: 1760 Governor Specifications Manufacturer: Woodward Serial No.: 15363644 Type: Electric/Hydraulic Built: July 2007 Approximate Dimensions: 131 ¼” L x 44 ½” W x 51 ½” H Approximate Shipping Weight: 6,000 Lbs
Location: Midwest USA
8300 kW Siemens Back Pressure Steam Turbine Generator Set
Stock #ZG63824
Used 8300 kw Siemens back pressure steam turbine generator set consists of following: STEAM TURBINE: Manufacturer: Siemens (Dresser-Rand) Frame: 1QS2BQ Rating: Rating at zero extra. Inlet steam: Controlled Extraction Exhaust steam 8351 KW 5,750 kw 448 psig/660 °F Maximum 458 psig/670 °F , right side 130 psig 0-80,000 lbs/hr, down 60 PSIG Maximum 70 psig , down Max. inlet flow Steam rate at zero extraction: 26.09 lbs/kwh Manufacturer Model no Inlet speed: Outlet speed Ratio: Serial No. GENERATOR: Manufacturer: Serial number: Type Rated Power: KW: Voltage: PF Speed: Exciter Rotation: Lufkin NFV24000 6038 rpm 1800 rpm 3.354:1 11148 Electrical Machinery 194342411 TEWAC , Brushless 10,439 kva 8351 KW 13,800 v,3 phase, 60 hz 0.8 1800 rpm 30 volts, 8 amps CCW from drive end 275,000 lbs/hr, Zero Extraction 150,000 lbs/hr Speed: Number of stages Rotation: Steam inlet: 12” #600 RF, Extraction steam 14” #300 RF, Exhaust steam 16” # 150 RF GEAR REDUCER 6038 rpm 4 rateau CW from Governor end SCOPE OF SUPPLY Steam Turbine, Gear reducer mounted on skid Inlet T & T valve 12” # 600 Exhaust expansion joint Generator with brushless exciter Generator terminal box with surge arrester and capacitor Air to water cooler Cooling water inlet and outlet isolation valve Extraction steam NRV Safety valves extraction line and exhaust steam line Woodward 505E governor, Woodward EGCP-3 digital control Lube oil tank, lube oil cooler, lube oil pump Lube oil purifier Gland steam system Manual and drawings Generator breaker with cts and pts can be supplied if needed additional cost Approximate shipping size and weights Steam turbine and gear reducer on skid Generator Auxiliries 3 flat bed trucks History Manufactured 1994, Shutdown: 2021 217” x 96” W x 131” H 71,480 lbs 209” L x 90” W x 85” H 55,000 lbs
Location: N/A
12000 kW 35 Bar Kaluga Turbogenerator Set
Stock #AG61862 Sold
Used back pressure turbogenerator set by Kaluga type P-12-35/5 with the capacity 12000 kW. Inlet steam pressure 35 bar, inlet steam temperature 435*C, back pressure 5 ATM. Steam consumption 94800 - 114700 kg/hour. Electrical power 9600-12000 kW. Additional information on request.
Location: East EUROPE
12000 kW 510/75 PSI Kaluga Steam Turbine Plant
Stock #ZS61313 Sold
Reportedly unused steam turbine plant "Kaluga turbine plant". Includes turbine model P-12-3.4/0.5 made by "Kaluga turbine plant" in 1996. Steam data:inlet steam absolute pressure 3,4 MPA (510 psi)@ 435 DEGC; discharge pressure 0.5 MPA (75 psi)@ 221 DEGC; steam flow rate approx.111,24TPH. Includes generator model T-12-2UZ made by Lisva in 1996. Power data: nominal power 12000 kW, 6300V, 3000rpm, 97,65%; excitation power data 230V@268a. Weight of turbine approx.35 ton, weight of generator approx.28 ton. All on long storage.
Location: EUROPE
12000 kW Lisva Generator
Stock #KG61408-2 Sold
Reportedly unused Lisva type T-12-2UZ generator only, suitable for Kaluga steam turbine plants rated 12MW. New in 1984.
Location: EUROPE
12500 kW 63 Bar Power Plant
Stock #AS61917 Sold
Used power plant with the electrical capacity 12500 KW. Main equipment of the plant is following: Tube type boiler with the steam output of 63 ton/hour, 480 degrees Celsius, 63 bar. Type of burners: 2 R&V burners type TTL/MG-22.5. Fuel - Fuel Oil/ Natural Gas/ Coal. Two back pressure Siemens turbogenerators, one with the electrical output 5500KW and another one with 7000KW. More information on request.
Location: N/A
1500 kW 15 Bar Kaluga Steam Turbogenerator Set
Stock #AG61861-01 Sold
Used back pressure steam turbogenerator set by Kaluga type op-1.5-3. Nominal capacity 1500 kW. Inlet stem flow pressure 15-21 bar, temperature 350*C. Back pressure 3 ATM. Size parameters - length 2961mm, width 2090mm, height 2262mm.
Location: EUROPE
2,000 Kw 298 Psi Triveni Back Pressure Steam Turbine Generator
Stock #ZS63428 Sold
Used Triveni (India) back pressure Steam Turbine Generator Set rated at 2,000 kW, new in 1978. Consisting of: - Triveni (India) type 550mm back pressure steam turbine, new in 1978, with inlet steam pressure 18/21 kg/cm2 @ 300 Deg.C, and exhaust steam pressure 0.95 kg/cm2. With Triveni (India) gearbox, new in 1978, input speed 8250 rpm and output speed 1500 rpm, ratio 5.5/1. - Kirloskar Electric Co. Ltd alternator, capacity 2500 kVA voltage 440V 3phase 50Hz,, complete with excitor, - Oil cooling system having oil coolers, oil filter, MOP and AOP with electric motor, inter-connected oil pipelines - Turbine local panel - Inlet and stop valves, exhaust bellow, More details upon request.
Location: ASIA
2,500 Kw 298 Psi Triveni Back Pressure Steam Turbine Generator
Stock #ZS63427 Sold
Used Triveni (India) back pressure Steam Turbine Generator Set rated at 2,500 kW, new in 1988. Consisting of: - Triveni (India) type 550mm back pressure steam turbine, new in 1988, with inlet steam pressure 19/21 kg/cm2 @ 300/340 Deg.C, and exhaust steam pressure 1.5 kg/cm2 @ 160 Deg.C. With Triveni (India) gearbox, new in 1988, input speed 8250 rpm and output speed 1500 rpm, ratio 5.5/1. Turbine & Gear box alongwith coupling mounted on common baseframe (oil tank). - BHEL alternator frame size AG-52/45, capacity 3125 kVA voltage 440V 3phase 50Hz, mounted on baseframe, - Oil cooling system complete with oil cooler, Oil Filters, AOP with electric motor, lot of all interconnecting oil pipelines, etc. - Alternator coolers, inlet valve, exhaust bellow - Governing System - Turbine control panel, AVR and ACB panels. More details upon request.
Location: ASIA
2000 kW Belliss Turbogenerator Set
Stock #AG61842-01 Sold
Used back pressure turbogenerator set with the capacity 2 MW, turbine made by Belliss type SPB-350, new in 2003, approximate steam consumption 32 TPH, inlet steam pressure 42 kg/cm2, exhaust pressure 1/1.5 kg/cm2, 10250 rpm. Generator by Crompton Geaves, new in 2003, 2000 kW, 2500 kVA, 1500 rpm, 420 V, 3 phases, 50 Hz. Scope of supply and additional information on request.
Location: ASIA
5000 kW 395/45 PSI General Electric Non-Condensing Turbogenerator
Stock #ZS54894 Sold
Used GE non-condensing turbogenerator rated 5000 kW producing power at 3 phase 60 HZ 4160 volt. Steam conditions: inlet 395 psi, exhaust 45 psi.
Location: N/A
6,000 Kw 640 Psi Ape Belliss Back Pressure Steam Turbine Generator
Stock #ZS63421 Sold
Used APE Belliss (India) back pressure Steam Turbine Generator Set rated at 6,000 kW, new in 2006. Consisting of: - APE Belliss type SBP450 steam turbine, new in 2006, with inlet steam pressure 42 kg/cm2 @ 420 Deg.C / 45 kg/cm2 @ 440 Deg.C., and exhaust steam pressure 1.5/2 kg/cm2. With Triveni (India) gearbox type HSG560S, input speed 8300 rpm and ratio 5.52/1 which gives output speed 1500 rpm. Both mounted on baseframe. - VA Tech generator capacity 7500 kVA voltage 11 kV 3phase 50Hz, mounted on baseframe, - Governing System for Turbine, - Oil cooling system with filters,tank etc, - Radiators for alternator cooling, - Excitor, control panels for turbine, alternator, AVR. Oil Cooler, Cables& VCB Panel are excluded. Reportedly slightly used. More details upon request.
Location: ASIA
6250 kW 600/95 PSI General Electric Steam Turbine
Stock #ZG60417 Sold
Manufacturer: General Electric type: condensing kW rating: 6,250 kW inlet steam pressure, PSIG: 600 PSIG operating temperature, ºF: 825ºF automatic extraction, PSIG: 95 PSIG exhaust pressure, inches of HG: 3.0” HG. Rpm: 3600 rpm year new: 1959 date last operated: 2006 direct connected to: generator: manufacturer: general electric capacity in kVA: 7,500 kVA power factor: 80% frequency: 60 hertz voltage: 2140/4160 volts speed: 3600 rpm cooling system: air cooled exciter: voltage: 125 volts
Location: South USA
720 Kw 469 Psi APE Belliss Back Pressure Steam Turbine Generator
Stock #ZS63429 Sold
Used APE Belliss (India) back pressure Steam Turbine Generator Set rated at 720 kW, new in 1987. Consisting of: - APE Belliss (India) type SSK 5AD back pressure steam turbine, new in 1987, with inlet steam pressure 33 kg/cm2 @ 400 Deg.C, and exhaust steam pressure 9 kg/cm2. With Walchandnagar Industries type GN25 gearbox, new in 1986, input speed 6000 rpm and output speed 1500 rpm, ratio 4/1. Turbine & Gearbox alongwith coupling mounted on common baseframe (oil tank). - Kirloskar Ltd alternator, capacity 1250 kVA voltage 440V 3phase 50Hz, including alternator panel, - AOP with motor, oil filters, oil pipelines, inlet valve, - Governing System More details upon request.
Location: ASIA
Unused back pressure steam turbine generator 6000 KW
Stock #AS60935 Sold
Unused back pressure steam turbine generator Kaluga P6-3,4/0,5-1 with the electrical output 6 MW. Main parameters of the steam turbogenerator: Electrical output 6000 KW. Inlet steam 34 bar, 435 degrees C. Outlet steam 0.5 bar, 225 degrees C. Steam consumption 57.9 tons per hour. Three phase, 50 HZ, cos 0.8.